Probe Store - FMM

For optimal performance with our AFM systems please request a quote from Park Systems. Mounted cantilevers are additionally tested. All probes that are not listed here from Nanosensors™, Nanotools GmbH, Nanoworld AG, BudgetSensors, Olympus Corp., MikroMasch, Applied Nano Structures, Inc. are possible to order from our probe store. Probes from other manufacturers also can be possible to order upon request for quotation. The peformance of probes ordered from other sources are not guaranteed.

Probe Force Constant (N/m) Frequency (kHz ) Manufacture Short Description Quote
PPP-FMR 2 75 Nanosensors ▪ Cantilever with force constant suitable for FMM
▪ Backside reflex coating (AI)
Request for Quote
Property Nominal Value Specified Range
Thickness /µm 3 2.0 - 4.0
Mean Width /µm 28 20 - 35
Length /µm 225 215 - 235
Force Constant /(N/m) 2 0.5 - 9.5
Resonance Frequency /kHz 75 45 - 115
DT-FMR 6.2 105 Nanosensors ▪ Cantilever with force constant suitable for FMM
▪ Backside reflex coating
▪ Diamond coated tip
Request for Quote
Property Nominal Value Specified Range
Thickness /µm 3 2.0 - 4.0
Mean Width /µm 27.5 20 - 35
Length /µm 225 215 - 235
Force Constant /(N/m) 6.2 1.5 - 18.3
Resonance Frequency /kHz 105 65 - 155
PPP-NCSTR 7.4 160 Nanosensors ▪ Cantilever with force constant suitable for FMM
▪ Backside reflex coating
Request for Quote
Property Nominal Value Specified Range
Thickness /µm 2.8 1.8 - 3.8
Mean Width /µm 27 19.5 - 34.5
Length /µm 150 140 - 160
Force Constant /(N/m) 7.4 1.2 - 29
Resonance Frequency /kHz 160 75 - 265
NSC36/Al BS 1
2
0.6
90
130
65
Mikromasch ▪ Contact cantilever
▪ Backside reflex coating (Al)
▪ 3 cantilevers on a chip
Request for Quote
.
NSC36,
Cantilevers
Resonance Frequency, kHz Force Constant, N/m Length
l ± 5,
µm
Width
w ± 3,
µm
Thickness
t ± 0.5,
µm
min typ max min typ max
A 30 90 160 0.1 1 4.6 110 32.5 1.0
B 45 130 240 0.2 2 9 90 32.5 1.0
C 25 65 115 0.06 0.6 2.7 130 32.5 1.0
NSC14/HARD/AI BS 5 160 Mikromasch ▪ Cantilever with force constant suitable for FMM
▪ Backside reflective coating (Al)
▪ Hard Diamond-Like-Carbon coated tip
Request for Quote
Cantilever Resonance Frequency, kHz Force Constant, N/m Length
l ± 5,
µm
Width
w ± 3,
µm
Thickness
t ± 0.5,
µm
min typ max min typ max
14 Series 110 160 220 1.8 5 13 125 25 2.1


 

Request Quote

Please fill in all required fields(*) to ensure we can process your request as quickly as possible.





To prove you are human, please select the icons:
 